Why maximum size depends on thickness
- Long, thin panels bend under their own weight in the tempering furnace, which limits flatness and size. Thicker glass stays flatter, so the largest panels are made in 10–12 mm.
- Very large panels also need special packing and container loading; tell us the sizes early so we can plan the crates.
Before tempering
- All cutting, edge work, holes and notches must be done before tempering; tempered glass cannot be cut or drilled afterwards.
- For facades and overhead glazing, consider heat-soak testing to reduce the risk of spontaneous breakage from nickel sulfide inclusions.
Choosing the thickness
- Thickness depends on panel size, support, wind or barrier load and the local code. The structural engineer confirms the final thickness.
- Send us your size list or drawing and we will confirm feasibility and quote per panel.