How to read an IGU specification
- 6+12A+6 = 6 mm glass, 12 mm air space (A = air), 6 mm glass. When the cavity is filled with argon it is often written 12Ar.
- Panes can be clear, tinted, tempered, heat-reflective, Low-E, laminated or ceramic-fritted. State which pane carries the Low-E coating and on which surface (usually surface 2 in warm and hot climates).
- A laminated pane is written with its build-up, for example 6+12A+(5+0.76+5).
Thermal performance
- The U-value and solar factor of a unit depend mainly on the Low-E coating, the gas fill and the cavity width, not on the glass thickness. Ask us for the coating data of the Low-E glass you are considering.
- For hot climates such as the Gulf, a solar-control Low-E coating with low solar heat gain is usually more important than triple glazing.
Sealing and edge
- Primary seal butyl; secondary seal polysulfide or structural silicone, chosen according to the glazing method. Structurally glazed curtain walls need a structural silicone secondary seal.
- Molecular sieve desiccant in the spacer keeps the cavity dry.