How to Read an Insulated Glass Unit (IGU) Specification
An insulated glass unit (IGU) specification is read from the outside of the building to the inside. A string such as 6 Low-E + 12A + 6 means a 6 mm outer pane with a low-emissivity coating, a 12 mm cavity filled with air, and a 6 mm inner pane. The full specification should also state which surface carries the coating, the spacer and sealant types, and the performance values the unit must achieve.
Reading the make-up notation
Most suppliers use a compact notation in which numbers are thicknesses in millimetres and letters describe the cavity or glass:
- 6 Low-E + 12A + 6: 6 mm Low-E glass, 12 mm air cavity, 6 mm clear glass.
- 6 + 12Ar + 6: two 6 mm panes with a 12 mm cavity filled with argon.
- 6 Low-E + 16A + 6.38: the inner pane is 6.38 mm laminated glass, usually two 3 mm plies with a 0.38 mm interlayer.
- 6 + 12A + 6 + 12A + 6: a triple-glazed unit with two cavities.
- T: often added to indicate tempered (toughened) glass, for example 6T Low-E + 12A + 6T.
Abbreviations are not fully standardised between suppliers, so ask for a written legend if anything is unclear. Always confirm the overall unit thickness against the frame rebate.
Surface numbering #1 to #4
In a double-glazed unit, glass surfaces are numbered from the outside inwards. Surface #1 faces the weather, #2 is the cavity side of the outer pane, #3 is the cavity side of the inner pane and #4 faces the room. Triple-glazed units run from #1 to #6.
Surface position matters because soft-coat Low-E and many solar-control coatings must be protected inside the sealed cavity, so they are placed on #2 or #3. In cooling-dominated climates the coating is commonly on #2 to reflect solar heat before it enters the cavity; in heating-dominated climates some designs place it on #3. The coating supplier's data and the energy model should decide the position.
Spacer types
The spacer holds the panes apart and defines the cavity width. It also forms a thermal path at the edge of the unit.
- Aluminium spacers are widely used, rigid and economical, but conduct heat, which can lower edge temperatures and increase the risk of condensation at the perimeter.
- Warm-edge spacers, made from stainless steel, polymer or composite materials, reduce heat flow at the edge and can improve the whole-window performance and edge condensation resistance.
If warm-edge spacers are required by the energy calculation, state this clearly and ask your supplier whether they can provide the specified system.
Primary and secondary seals
Most IGUs use a dual-seal system. The primary seal is polyisobutylene (butyl), applied between the spacer and the glass; it is the main barrier against moisture vapour and, in gas-filled units, gas loss. The secondary seal fills the outer channel around the spacer and gives the unit structural integrity. Common secondary sealants are polysulfide, polyurethane and silicone.
Where the edge of the unit is exposed to UV or where the unit is structurally bonded in a curtain wall, a silicone secondary seal is normally required and must be compatible with the structural silicone. Confirm this with the facade engineer and sealant manufacturer.
Desiccant and gas fill
The hollow spacer contains a desiccant, typically a molecular sieve, which absorbs moisture trapped during assembly and any vapour that diffuses through the seals over time. Without it, condensation would form inside the cavity.
The cavity is filled with dry air or with an inert gas such as argon. Argon conducts heat less than air, so it lowers the U-value for the same make-up. Performance depends on the fill level being maintained, which in turn depends on seal quality. If argon is specified, ask the supplier how the fill is achieved and checked.
Performance values: U-value, SHGC and VLT
| Term | What it means | Better when |
|---|---|---|
| U-value (W/m2K) | Rate of heat transfer through the glazing | Lower |
| SHGC or g-value | Fraction of solar heat that passes into the building, from 0 to 1 | Lower for cooling, higher for passive heating |
| VLT | Visible light transmittance, the share of daylight passing through | Depends on daylight and glare targets |
| Reflectance | Share of visible light reflected outside and inside | Depends on appearance requirements |
Check whether quoted values are centre-of-glass figures or whole-window figures; the latter include the frame and spacer and will differ.
Standards
In Europe, EN 1279 covers insulating glass units, including durability, moisture penetration and gas retention testing. Projects in other regions may refer to their own national standards, so state the requirement in the tender.
IGU specification checklist
- Make-up from outside to inside, with thicknesses and overall unit thickness.
- Glass type for each pane: annealed, heat-strengthened, tempered or laminated.
- Coating type and surface position.
- Cavity width and fill: air or argon.
- Spacer type and colour.
- Secondary sealant type, and any structural silicone compatibility requirement.
- Required U-value, SHGC and VLT, and whether they are centre-of-glass or whole-window.
- Applicable standard, labelling and sizes with tolerances.
Conclusion
Reading an IGU specification is mostly a matter of working from outside to inside and checking that each component is defined: glass, coating position, cavity, spacer, seals and performance targets. A complete specification avoids substitutions, mismatched frames and disputes about performance after installation.